Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the collectchat domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home1/aycingen/public_html/wp-includes/functions.php on line 6114

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the woocommerce-checkout-manager domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home1/aycingen/public_html/wp-includes/functions.php on line 6114

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the essential-addons-for-elementor-lite domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home1/aycingen/public_html/wp-includes/functions.php on line 6114

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the forminator domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home1/aycingen/public_html/wp-includes/functions.php on line 6114

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the woocommerce domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home1/aycingen/public_html/wp-includes/functions.php on line 6114

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the rocket domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home1/aycingen/public_html/wp-includes/functions.php on line 6114

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the wordpress-seo domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home1/aycingen/public_html/wp-includes/functions.php on line 6114

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the breadcrumb-navxt domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home1/aycingen/public_html/wp-includes/functions.php on line 6114
Unidad de filtro y regulador 310 l/min FESTO - A&C Ingeniería
November 13, 2024
Soporte especializado: (601) 7030290
- (+57) 314 3237624
E-mail: publicidad1@aycingenieria.com

Unidad de filtro y regulador 310 l/min FESTO

Las unidades de filtro y regulador de 310 l/min de FESTO garantizan un flujo constante de aire limpio y regulado en entornos industriales. Compactas y eficientes, son fabricadas por FESTO, líder en automatización industrial, asegurando un rendimiento óptimo de los sistemas neumáticos.

Descarga información de producto

 

Nota: Productos sujetos a disponibilidad en almacén.

 

Haz click aquí y contáctate con nuestros especialistas en ventas

SKU: MS2-LFR-QS6-D6-C-P-M-AR-MPA-B Category: Tag:

Las unidades de filtro y regulador de 310 l/min de FESTO ofrecen una solución compacta pero eficaz para el control del aire comprimido en entornos industriales. Con una capacidad de 310 litros por minuto, estas unidades garantizan un flujo constante de aire limpio y regulado, esencial para mantener el rendimiento óptimo de los sistemas neumáticos. Fabricadas por FESTO, una marca líder en automatización industrial, estas unidades incorporan tecnología avanzada para proporcionar una filtración precisa y una regulación precisa de la presión del aire. Perfectas para aplicaciones de menor escala o donde el espacio es limitado, las unidades de filtro y regulador de 310 l/min de FESTO ofrecen confiabilidad y eficiencia en cualquier entorno industrial.

Tamaño:

2

Serie:

MS

Bloqueo del accionamiento:

Botón giratorio con bloqueo

Posición de montaje:

Vertical +/- 5°

Purga de condensado:

Giro manual

Forma constructiva:

Filtro regulador con manómetro

Volumen máx. de condensado:

3 ml

Función del regulador:

Presión inicial constante
Con escape de aire secundario
Con flujo inverso

Símbolo:

00991589

Unidad(es) representable(s):

MPa

Indicador de presión:

Con manómetro

Presión de funcionamiento-1:

0.1 MPa … 0.8 MPa

Presión de funcionamiento-2:

1 bar … 8 bar

Margen de regulación de presión:

0.5 bar … 7 bar

Histéresis máxima de la presión:

0.025 MPa

Histéresis máx. de la presión /Histéresis máx. de la presión:

0.25 bar

3.625 psi

Caudal nominal normal (normalizado según DIN 1343):

310 l/min

Medio de funcionamiento:

Aire comprimido según ISO 8573-1:2010 [7:4:4]
Gases inertes

Clase de resistencia a la corrosión CRC:

1 – riesgo de corrosión bajo

Conformidad PWIS:

VDMA24364-B1/B2-L

Clase de sala limpia:

Clase 7 según ISO 14644-1

Temperatura de almacenamiento:

-5 °C … 50 °C

Clase de pureza del aire en la salida:

Aire comprimido según ISO 8573-1:2010 [6:4:4]

Temperatura del medio:

-5 °C … 50 °C

Temperatura ambiente:

-5 °C … 50 °C

Peso del producto:

43.5 g

Tipo de fijación:

A elegir:
En panel frontal
Instalación en la tubería
Con accesorios

Conexión neumática 1:

QS-6

Conexión neumática 2:

QS-6

Nota sobre el material:

Conformidad con la Directiva RoHS

Material de las juntas:

NBR

Material del botón giratorio:

POM

Material del muelle:

Acero de alta aleación

Material del filtro:

PE

Material del cuerpo:

Reforzado con PA

Material de la funda:

PC

Material de la leva de la válvula:

POM